Industrial Power. Enterprise Data. One Integrated Platform.
Uptime (target)
99.98%
PUE (design target)
<1.35
MW Available
300MW
From Megawatts to Mission-Critical
Our data centers convert large-capacity power into high-density, low-PUE compute with the governance and SLAs institutional clients expect. Built on pre-permitted, grid-connected sites, Sonamu facilities compress timelines and de-risk deployment.
Highlights
-
Built for AI/HPC, blockchain, and enterprise cloud
-
Rapid energization on pre-permitted power footprints
-
Consistent PUE < 1.35 targets with redundant, serviceable designs
Power-to-Compute Flow
Utility power enters, is conditioned and distributed, then converted into high-density compute inside modular pods—delivered securely over the core network to client workloads.
Reliability by Design. Efficiency by Default.
-
Modularity: containerized or hall-based blocks (10–30MW pods) enable phased growth.
-
Cooling Intelligence: liquid & immersion for GPU/ASIC; hot-aisle containment for mixed racks.
-
Power Integrity: N/N+1 topologies; smart switchgear; automated transfer & isolation.
-
Observability: SCADA + OT/IT telemetry; real-time power, thermal, and capacity analytics.
-
Maintainability: clear service corridors, hot-swap loops, and standardized MOP/SOP/EOP.
Traditional Data Center vs. Sonamu HCC Environment
Lower PUE. Higher uptime. Greater scalability. A side-by-side snapshot of operational efficiency and capacity growth.
Traditional Data Center
Conventional air-cooled design, slower to scale, higher overhead.
PUE
1.70–2.0
Uptime
≈ 99.9%
Scalability
Pod 5–10 MW
Sonamu HCC Environment
High-density, liquid/immersion cooling with integrated power strategy.
PUE
< 1.35
Uptime
≈ 99.98%
Scalability
Pod 10–30+ MW
Tiered, High-Density, Fiber-Rich.
-
Power: dedicated substation or dedicated feeders; 13.8–138kV intake, step-down, ring main.
-
Distribution: 415V or 240V rack feeds; busway; per-pod meters & curtailment control.
-
Cooling: immersion skids, CDU/plate exchangers, and DX/evap assist where climate-advantaged.
-
Density: 10–35 kW/rack (air), 30–100+ kW/rack (liquid/immersion).
-
Networking: carrier-neutral, diverse fiber entrances; 25/40/100/400G options; segmented core/edge.
Carrier Choice, Segmented Fabrics, Audited Controls.
-
Connectivity: diverse paths, on-net carriers, cloud on-ramps, private wave options.
-
Segmentation: tenant L2/L3 isolation, micro-segmented mgmt networks, out-of-band access.
-
Physical Security: multi-factor access, mantraps, segmented cages/halls, CCTV with retention.
-
Compliance-ready: support for SOC 2, ISO 27001, and client-driven control mapping.
Institutional Operations, Measurable Outcomes.
-
Uptime Target: 99.98% with N/N+1 (or better) power & cooling.
-
Monitoring: 24×7 NOC; predictive maintenance; automated runbooks.
-
Energy Strategy: ERCOT/market integration for cost control and demand response revenue.
-
Reporting: monthly service reports; capacity & efficiency dashboards.
“We run utility-scale infrastructure with enterprise discipline.”
Choose Your Path to Capacity.
-
Colocation (Cages/Racks): rapid start, shared MEP, metered power.
-
Dedicated Halls: 5–20MW private halls; tailored density & security.
-
Powered Shell: Sonamu delivers the power & envelope; you fit out white space.
-
Build-to-Suit: fully bespoke design, delivered on Sonamu’s grid-connected land.
Performance Targets (Typical)
| Metric | Target |
|---|---|
| PUE (design) | < 1.35 |
| Rack Density | 30–100+ kW (liquid/immersion) |
| Uptime | 99.98% |
| Expansion Blocks | 10–30MW pods |
| Deployment | 12–18 months (acquire → operate) |